Because there is no conduit the depth requirement increases to 18 inches.
Underground electric cable depth uk.
Laying uf underground feeder cable directly into the ground this is known as direct burial and if you do this the uf cable must be at least 24 inches below the surface of the ground to minimize the chance of the cable being pierced by routine shoveling.
For a 6 in deep trench use galvanized rigid metal electrical conduit with individual conductors inside.
The sheath on such a cable is clearly marked as uf and the colours can vary.
Further the vertical runs where the cable descends into the ground at the house side and emerges up from the ground at the outbuilding.
All cables and ducts for lv mains and 11kv circuits are to be installed by central networks or its agents.
The national electric code nec sets the required burial depth of electric wire in rigid non metallic conduit such as pvc at 18 inches.
More information about underground cables and electrical safety is available in hse s avoiding danger from underground services.
Underground feeder uf cable is encased in weatherproof sheathing and can be directly buried in a trench.
Running underground cables in metal conduits approved for buried cables is the most expensive method but also the one requiring the least digging.
You may also run them at a depth of 4 inches under a 4 inch concrete slab.
Polypipe rigiduct outside diameter is 38mm.
The plans are only a guide.
Underground cable for running electrical power to a remote location can be installed at different depths depending on the type of conduit and type of wire used.
Surface fixed cables should be fixed to permanent structures only and should be supported at sufficient height above the ground to avoid accidental contact.
Must be laid with electrical cable warning tape which should be installed at a depth of 240mm below gardens and paths 100mm below roads and 650mm below agricultural land.
The position of the cables should be confirmed by proper use of location equipment and the application of safe digging techniques.
Electrical installations installed in a garden including luminaires and their associated cables should be securely fixed and protected against accidental damage and attack by rodents.
Electrical wire encased in pvc conduit.
Underground utility depths for water gas and electricity supply pipes and cables.
Cable in any conduit including pvc that is buried at this depth is not in danger of being severed or disturbed by normal digging.
Electrical cable depth options.
In this diy guide you will learn about the required depths that utility supply pipes and cables such as water pipes gas pipes and electrical supply cables need to be buried to in order to reduce the risk of damage when excavating and digging in the ground.